Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-OA16IK | Allen-Bradley ControlLogix Isolated AC Output Module

  • Model 1756-OA16IK
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$217.00 Indicative price · request a quote for availability

Allen-Bradley 1756-OA16IK ControlLogix isolated AC output module with 16 individually isolated points, 74-265V AC range, and conformal coating for harsh plant environments.

Product Description

When Downtime Isn’t an Option: The 1756-OA16IK Story

Plant floors have changed. Where relay panels once clicked through every start and stop, modern process lines now demand dense, isolated switching that survives heat, vibration, and the occasional washdown. The Allen-Bradley 1756-OA16IK was built for exactly that shift. As a ControlLogix isolated AC output module, it packs 16 individually isolated outputs into a single slot, letting you drive AC loads directly without external interposing relays on every point.

Figure 1: Front view of the Allen-Bradley 1756-OA16IK industrial automation component showing its physical design and enclosure.

What the 1756-OA16IK Actually Does

This module belongs to the Rockwell Automation ControlLogix series and carries the Allen-Bradley brand. It is an isolated AC output module rated for a 120-240 Volts AC voltage class, with an operating voltage range of 74-265 Volts AC. The 16 outputs are individually isolated, which matters when you are mixing circuits that must not share a common reference. Isolation voltage is rated at 50 Volts continuous. The module ships conformally coated, giving the circuitry a protective layer against moisture, dust, and airborne contaminants common in oil, gas, and heavy industrial settings.

Technical Specifications

Specification Value
Series ControlLogix
Module Type Isolated AC Output Module
Outputs 16 Points Individually Isolated
Voltage 120-240 Volts AC
Operating Voltage Range 74-265 Volts AC
Isolation Voltage 50 Volts Continuous
Power Dissipation (Max) 5.5 Watts at 60 degrees Celsius
Backplane Current at 5 Volts 300 milliamps
Backplane Current at 24 Volts 3 milliamps
Removable Terminal Blocks 1756-TBCH, 1756-TBS6H

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-OA16IK industrial automation component.

Where It Earns Its Keep

In upstream oil and gas, this module suits wellhead control panels where AC solenoids and pilot valves must switch independently. Each isolated point keeps a fault on one circuit from dragging down its neighbors, which protects both the process and the ControlLogix chassis.

In water treatment and pipeline pump stations, the 74-265 Volts AC range covers the wide voltage swings that come with long feeder runs. The conformal coating adds a layer of resilience in humid or coastal installations.

For retrofit projects, the 1756-OA16IK is a practical replacement path when older AC output cards reach end of service. The 36-pin terminal interface and removable block options keep wiring changes manageable during a scheduled outage.

Integration and Setup Notes

The module slots into a ControlLogix chassis and draws 300 milliamps from the 5 Volt backplane and 3 milliamps from the 24 Volt backplane. Plan your power budget accordingly. Removable terminal blocks 1756-TBCH and 1756-TBS6H simplify field wiring and let you pre-terminate before swapping hardware.

Because the outputs are individually isolated, verify each field circuit’s voltage and return path before commissioning. Keep wiring separated from low-level analog signals to reduce noise coupling. If you are tying this module into a larger network architecture, confirm gateway and cable requirements with your supplier.

Maintenance and Long-Term Reliability

Inspect terminal connections periodically for looseness and heat discoloration. Keep the chassis airflow path clear, since the module dissipates up to 5.5 Watts at 60 degrees Celsius. In dirty environments, check that the conformal coating remains intact and follow your facility’s standard cleaning and inspection schedule. Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Choosing the Right Output Module

Before you commit, confirm your field device voltage falls within 74-265 Volts AC and that your point count matches the 16 available outputs. Decide whether you need the 1756-TBCH or 1756-TBS6H terminal block for your wiring style. Oil AutoTech offers hands-on technical selection help and fast dispatch, worldwide, so you can get spares when you need them. Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-OA16IK
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $217.00

Additional Information

Mfr. Part Number:
1756-OA16IK
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen-Bradley 1756-OA16IK ControlLogix Isolated Output Module 74-265V AC 16-Ch
Full Description: Allen Bradley 1756-OA16IK ControlLogix Isolated Output Module, 74-265V AC, 16 Individually Isolated Outputs 36-Pin, Conformally CoatedAllen Bradley ControlLogix Isoloated AC Output Module with 16 Points Individually Isolated Outputs Technical specifications for 1756-OA16IK
Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 1756-OA16IK
Series ControlLogix
Module Type Isoloated AC Output Module
Outputs 16 Points Individually Isolated
Voltage 120-240 Volts AC
Operating Voltage Range 74-265 Volts AC
Maximum Output Current Rating-Point 2 Amps at 30 degrees Celsius, 1 Amp at 60 degrees Celsius
Maximum Output Current Rating-Module 5 Amps at 30 degrees Celsius, 4 Amps at 60 degrees Celsius
Power Dissipation (Max) 5.5 Watts at 60 degrees Celsius
Backplane Current at 5 Volts 300 milliamps
Backplane Current at 24 Volts 3 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-OA16IK_Service_Manual)

Latest News

View All News