Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Vibro Meter

111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10 | Vibro-Meter Proximity System

  • Model 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10
  • Type Communication Modules
  • Condition In Stock
4.6/5 (16 reviews)
$278.00 Indicative price · request a quote for availability

Vibro-Meter proximity measuring system with Ex i rating, M10x1 thread, 1 m integral cable, and 10 m total length. Ready-to-ship for API 670 applications.

Product Description

Product Overview

Downtime in oil, gas, and industrial automation often traces back to a single failed measurement chain. The Vibro-Meter 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10 is a proximity measuring system built to keep those chains running. As part of the vibro-meter product line, this transducer uses the eddy-current principle for non-contact shaft vibration and gap/position measurement. It carries an Ex i rating for hazardous areas and conforms to API 670 recommendations.

With a 30 mm body length, M10 x 1 thread, and 1.0 m integral cable, this unit fits standard machinery protection installations. The total system length reaches 10 m, and the assembly weighs just 0.22 kg.

Figure 1: Front view of the Vibro Meter 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10 industrial automation component showing its physical design and enclosure.

Technical Specifications

Parameter Value
Product Type Proximity Measuring System
Environment Explosive Ex i
Body Thread M10 x 1
Body Length 30 mm
Integral Cable Length 1.0 m ±100 mm
Total System Length 10 m
Weight 0.22 kg
Measurement Range 2 or 4 mm
Frequency Response DC to 20 kHz (-3 dB)
Temperature Range (Transducer) -40 to +180 C
Protection Rating IP68 (transducer head)
Vibration 5 g peak, 10 to 500 Hz
Shock 15 g peak, 11 ms half sine

Why This Configuration Works

The 30 mm body length with M10 x 1 thread suits tight mounting spaces on bearing housings and gearboxes. The 1.0 m integral cable connects to extension cables without adapters, reducing connection points. The transducer head is IP68-rated, so moisture and dust stay out. A temperature-compensated design keeps drift below 5% across -40 to +180 C. The frequency response reaches DC to 20 kHz, capturing both slow drift and high-frequency vibration events.

Figure 2: Technical layout and connection details for the Vibro Meter 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10 industrial automation component.

Applications in Oil, Gas, and Industrial Automation

Compressor and turbine monitoring: This transducer feeds shaft relative vibration data into VM600Mk2/VM600 and VibroSmart machinery monitoring systems. The Ex i rating allows installation in Zone 0, 1, or 2 hazardous areas.

Pump and motor condition monitoring: The 2 or 4 mm measurement range covers typical gap/position checks on rotating equipment. The stainless steel body (AISI 316L) resists corrosion in offshore and chemical plant environments.

API 670 compliance: For facilities following API 670 recommendations, this system provides the measurement chain needed for machinery protection.

Installation and Integration

The transducer requires a high-frequency power source from an IQS900 signal conditioner. The self-locking miniature coaxial connectors hand-tighten until locked, so no tools are needed. When wiring into fieldbus networks or control systems, an external gateway or connection module may be required. Confirm cables and gateways with your supplier before commissioning.

For Ex installations, follow the manufacturer’s safety manual and local hazardous area regulations. Do not substitute cables or connectors unless approved for the application.

Maintenance and Reliability

Inspect the transducer tip and cable periodically for mechanical damage. The FEP-covered coaxial cable resists chemicals and moisture. In high-vibration areas, check the connector tightness at scheduled intervals. The stainless steel body handles washdown and corrosive atmospheres. For Ex Zone installations, cable and connector temperature limits reach -40 to +200 C.

Selection Checklist

Before ordering, verify your measurement range (2 or 4 mm), cable length requirements, and hazardous area classification. Confirm compatibility with your existing signal conditioner and monitoring system. The 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10 ships ready-to-use with no flexible hose or optional protection.

Please verify current lifecycle status and availability with Oil AutoTech before ordering. Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10
Product Type Communication Modules
Brand Vibro Meter
Condition In Stock
Origin US
Warranty 12 Month
Price $278.00

Additional Information

Manufacturer : Meggitt (Vibro-Meter)

Product No. : 111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10

Product Type : Proximity Measuring System

111-402-000-013

Environment (A) : 2 = Explosive Ex i

Body thread (B) : 1 = M10 × 1
Body length (C):030=30 mm
Unthreaded length (D): 000=0 mm min.

Integral cable length (E) : 010 = 1.0 m ±100 mm

Optional protection (F) : 0 =None

Flexible hose length (G) : 000 = None

Total system length (H) : 10 = 10 m

Weight : 0.22 Kg

KEY FEATURES AND BENEFITS
From the vibro-meter® product line
Non-contact measurement system based on
eddy-current principle
Ex certified versions for use in hazardous areas
(potentially explosive atmospheres)
Conforms to API 670 recommendations
1, 5 and 10 m systems
Temperature-compensated design
Voltage or current output with protection
against short circuits
Frequency response:
DC to 20 kHz (−3 dB)
Measurement range:
2 or 4 mm
Temperature range:
−40 to +180 °C
APPLICATIONS
Shaft relative vibration and gap/position
measurement chains for machinery
protection and/or condition monitoring
Ideal for use with VM600Mk2/VM600 and
VibroSmart® machinery monitoring systems
API 670 applications

General
Transducer input requirements : High-frequency power source from an IQS900 signal conditioner
Environmental
Temperature ranges
Transducer : −40 to +180°C with drift 5% (short-term survival).
Transducer and cable : −40 to +195°C if used in an Ex Zone
Cable, connector and optional
protection
: −40 to +200°C
Protection rating
(according to IEC 60529)
: The head of the proximity transducer (transducer tip and integral
cable) is rated IP68
Vibration
(according to IEC 60068-2-26)
: 5 g peak between 10 and 500 Hz
Shock acceleration
(according to IEC 60068-2-27)
: 15 g peak (half sine-wave, 11 ms duration)
Physical characteristics
Transducer construction : Wire coil Ø8 mm, Torlon (polyamide-imide) tip, encapsulated in
stainless steel body (AISI 316L) with high-temperature epoxy glue
Integral and extension cables : FEP covered 70 Ω coaxial cable, Ø3.6 mm
Connectors : Self-locking miniature coaxial connectors.
Note: When connecting, these should be hand-tightened until
locked.
Optional protection
Flexible stainless steel hose
(protection tube)
: The stainless steel hose provides additional mechanical protection
but is not leak-tight
FEP sheath
(extruded fluorinated ethylene
propylene)
: The FEP sheath provides resistance to almost all chemicals and low
permeability to liquids, gases and moisture. It is also flexible, low
friction and mechanically tough.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Vibro_Meter_111-402-000-013-A2-B1-C030-D000-E010-F0-G000-H10_Service_Manual)

Latest News

View All News