Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-IV16 | Allen-Bradley ControlLogix 16-Point DC Input Module

  • Model 1756-IV16
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$284.00 Indicative price · request a quote for availability

Allen-Bradley 1756-IV16: 16-point ControlLogix DC input module with 10-30 VDC range. Fast-dispatch spares for oil, gas and automation. Contact Oil AutoTech.

Product Description

Product Overview

Downtime on a ControlLogix line rarely waits for a purchase order. The Allen-Bradley 1756-IV16 digital DC input module keeps 16 field signals feeding your processor, and it is built for the voltage swings common in oil, gas and heavy industrial cabinets. This module suits plants that measure cost in lost production hours, not in catalog pages.

Figure 1: Front view of the Allen-Bradley 1756-IV16 industrial automation component showing its physical design and enclosure.

Technical Specifications

Specification Value
Inputs 16
Input Voltage 12-24 Volts DC
Operating Voltage Range 10-30 Volts DC
Backplane Current at 5 Volts 110 milliamps
Backplane Current at 24 Volts 2 milliamps
Maximum Input Current, Off-State 1.5 milliamps
Power Dissipation (Max) 5.41 Watts at 60 degrees Celsius

Why These Ratings Matter

A wide operating range of 10-30 Volts DC means the 1756-IV16 tolerates the supply sag and surge that field wiring produces over long cable runs. Fewer nuisance trips translate directly into fewer unplanned shutdowns, and that is where the real savings sit.

Backplane current draw stays modest at 110 milliamps on the 5 Volt rail and 2 milliamps on the 24 Volt rail. In a densely packed chassis this leaves headroom for additional modules, so you avoid adding another power supply just to expand I/O.

Off-state current of 1.5 milliamps keeps leakage low, which protects input readings from false triggers caused by induced noise on long runs. Cleaner signals mean less time spent chasing phantom faults during commissioning.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-IV16 industrial automation component.

Where the 1756-IV16 Fits

On a gas compression skid, this module reads pressure switch and valve position contacts back to the ControlLogix processor. The 10-30 Volts DC range handles the voltage drop across long field runs without extra signal conditioning.

In a pipeline pump station, the 16 inputs let one module cover a full group of status contacts, reducing the number of cards you stock. Fewer spare part numbers on the shelf lowers inventory cost while keeping critical coverage.

For water treatment and process plants, the same module handles discrete device feedback where cabinet temperatures climb. Its 5.41 Watt maximum dissipation at 60 degrees Celsius keeps thermal load predictable inside sealed enclosures.

Integration Notes

The 1756-IV16 works with the ControlLogix 1756 chassis and uses an input data format only. It requires a removable terminal block housing before mounting, available as the 1756-TBNH or 1756-TBSH. Confirm your terminal block choice with your supplier when ordering.

Selection Checklist

Before you buy, verify the chassis slot, confirm the terminal block housing you already have on hand, and match the module to your field voltage. Oil AutoTech offers hands-on technical selection help and fast dispatch, worldwide, so your line is not waiting on a shelf search.

FAQs

Q: What voltage range does the 1756-IV16 accept?

A: The operating voltage range is 10-30 Volts DC, with a nominal input voltage of 24 Volts DC.

Q: How many inputs does this module provide?

A: It provides 16 inputs arranged in 2 groups of 8 points each.

Q: Which terminal block does it need?

A: It requires a removable terminal block housing, either the 1756-TBNH or the 1756-TBSH.

Q: What is the maximum off-state current?

A: The maximum off-state current is 1.5 milliamps.

Q: Is this module compatible with the ControlLogix chassis?

A: Yes, it is designed for the ControlLogix 1756 chassis and uses an input data format only.

Specifications

Model / No. 1756-IV16
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $284.00

Additional Information

The Allen-Bradley 1756-IV16 digital sourcing I/O module is manufactured by Allen-Bradley/Rockwell Automation. The 1756-IV16 input module comes with 16 inputs available in 2 groups, and 8 points in a group. It is compatible and it works with the ControlLogix 1756 chassis, it needs a detachable terminal block frame, or RTB, that can be the 1756-TBSH or the 1756-TBNH, before attaching it to the chassis. Only the input data format can be used by this module. The operating voltage for the 1756-IV16 module ranges between 10 and 30 Volts DC. It has a 12 to 24 Volts DC source voltage category, with a nominal input voltage of 24 Volts DC. The total backplane power is 0.61 Watts, with a maximum inrush current of 250 mA.

The 1756-IV16 module has a maximum input impedance of 3.2 kΩ at 30 Volts DC, and a maximum power dissipation of 5.1 Watts at 60 degrees Celsius, with a thermal dissipation of 18.47 BTU/hour. The module structures a continuous isolation voltage of 250 Volts. In an off-state, the 1756-IV16 has a maximum voltage of 5 Volts DC as well as a maximum current of 1.5 mA. When the module is in an on-state, it has a current range of as low as 2 mA at 10 Volts DC and a maximum of 10 mA at 30 Volts DC. The 1756-IV16 module comes equipped with a screw to the backplane input delay time. The variation depends on whether it is going from ‘off' to 'on' or vice versa. When going from 'off' to 'on', the input delay time is the hardware delay with a nominal time of 280 microseconds along with a maximum time of 1 millisecond plus the user-selectable filter time (which is either 0 milliseconds, 1 millisecond, or 2 milliseconds). When going from 'on' to 'off, the input delay time is the hardware delay time has a nominal of 540 microseconds along with a maximum of 2 milliseconds. In addition, there is the user-selectable filter time (1 millisecond, 2 milliseconds, 9 milliseconds, or 18 milliseconds). Allen Bradley ControlLogix Digital DC Input Module with 16 Inputs Technical specifications for 1756-IV16
Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 1756-IV16
Series ControlLogix
Module Type Digital DC Input Module
Inputs 16
Input Voltage 12-24 Volts DC
Operating Voltage Range 10-30 Volts DC
Input Delay Time 2 milliseconds plus selected filter time
Minimum Operating Current 2 milliamps at 10 Volts DC
Maximum Operating Current 10 milliamps at 30 Volts DC
Maximum Input Current, Off-State 1.5 milliamps
Power Dissipation (Max) 5.41 Watts at 60 degrees Celsius
Backplane Current at 5 Volts 110 milliamps
Backplane Current at 24 Volts 2 milliamps
UPC 10612598264343 Description
The Allen-Bradley 1756-IV16 is a digital sourcing I/O module. This input module has 16 inputs available, with 8 points in a group. Compatible with the ControlLogix 1756 chassis, it requires a removable terminal block housing, or RTB, which can either be the 1756-TBNH or 1756-TBSH before it can be attached to the chassis. Only an input data format is used by this module. The operating voltage range of the 1756-IV16 module is from 10 to 30 Volts DC and it has a 12/24 Volt DC source voltage category. It also has a nominal input voltage of 24 Volts DC. Its total backplane power is 0.61 Watts and maximum inrush current is 250 milliamps. The 1756-IV16 has a maximum input impedance of 3.2 kΩ at 30 Volts DC, a maximum power dissipation of 5.1 Watts at 60 Degrees Celsius, and a thermal dissipation of 18.47 BTU/hour. It also has a continuous isolation voltage of 250 Volts. During an off-state, this module has a maximum voltage of 5 Volts DC and a maximum current of 1.5 milliamps. When it is in an on-state, the 1756-IV16 has a current range of a minimum of 2 milliamps at 10 Volts DC and a maximum of 10 milliamps at 30 Volts DC. The 1756-IV16 module has a screw to backplane input delay time. This varies depending on if it going from an 'off' to 'on' state or vice versa. The input delay time when going from 'off' to 'on' is the hardware delay (with a nominal of 280 microseconds and a maximum of 1 milliseconds) plus the user-selectable filter time (either 0 milliseconds, 1 milliseconds, or 2 milliseconds). If going from 'on' to 'off, the input delay time is the hardware delay time (with a nominal of 540 microseconds and a maximum of 2 milliseconds) plus the user selectable filter time (either 1 milliseconds, 2 milliseconds, 9 milliseconds, or 18 milliseconds).、

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-IV16_Service_Manual)

Latest News