Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1769-DPS | Allen-Bradley PROFIBUS DP Slave Module

  • Model 1769-DPS
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$244.00 Indicative price · request a quote for availability

Allen-Bradley 1769-DPS PROFIBUS DP slave module for CompactLogix and MicroLogix 1500 systems. 9.6 kbps to 12 Mbps, 244 bytes I/O, backplane-powered.

Product Description

What Is the 1769-DPS?

The Allen-Bradley 1769-DPS is a PROFIBUS DP slave communication module built for CompactLogix and MicroLogix 1500 systems. It lets an Allen-Bradley controller operate as a slave node on a PROFIBUS-DP network, exchanging cyclic process and control data with a PROFIBUS DP master. This is an Encompass third-party module, so it is not a Rockwell first-party catalog item.

For plants running mixed control architectures, that role matters. Many facilities keep a PROFIBUS segment alive for drives, remote I/O, or legacy skids while standardizing the rest of the line on CompactLogix. The 1769-DPS bridges that gap without a full network migration.

Figure 1: Front view of the Allen-Bradley 1769-DPS industrial automation component showing its physical design and enclosure.

Key Technical Parameters

Specification Value
Function PROFIBUS-DP slave
Baud rate 9.6 kbps to 12 Mbps
Station address 1-126 via rotary switch
Data capacity Up to 244 bytes input / 244 bytes output
Power Backplane-powered (5V DC)
Dimensions 131 x 40 x 86 mm
Operating temperature 0 to 60 C
Approvals CE/UL (Encompass)

Baud Rate and Data Throughput

The 9.6 kbps to 12 Mbps range covers slow legacy segments and fast cyclic exchange on the same hardware. At the top end, 12 Mbps suits time-sensitive control data. At the low end, the module still talks to older PROFIBUS devices that never needed high speed.

Address Configuration

A rotary switch sets the station address from 1 to 126. That is a practical detail for maintenance teams: no software tool is required to change the node address on the bench or in the panel. Configuration is completed through the rotary switch and configuration software.

Backplane Power

The module draws 5V DC from the 1769 backplane, so it needs no separate field power supply for its own operation. In a CompactLogix chassis, the 1769 power supply module feeds the bus, supporting up to eight I/O modules per side of the supply.

Where the 1769-DPS Fits

Mixed-Protocol Production Lines

A packaging line may use a CompactLogix controller for sequencing while a PROFIBUS DP master coordinates variable-frequency drives. The 1769-DPS lets the CompactLogix side join that network as a slave, so process data moves without replacing the drives.

Legacy Skid Integration

Older compressor or metering skids often expose only PROFIBUS DP. Rather than rebuild the skid controls, engineers add the 1769-DPS to the CompactLogix rack and exchange the data the master expects.

Staged Upgrades

When a full network changeover is planned for a later shutdown window, the 1769-DPS keeps production running in the meantime. It is a practical bridge for phased migration work.

Installation Notes

The 1769-DPS follows standard Bulletin 1769 mounting practice. It installs on a panel with two screws or on DIN rail, locks to adjacent modules through tongue-and-groove, and shares the integrated bus through a movable bus connector. It plugs onto the controller’s right-side expansion bus.

Set the rotary address switch before power-up, and confirm the address is unique on the PROFIBUS segment. Keep the module within the 0 to 60 C operating range and allow normal panel ventilation.

Integration Note

Wiring a 1769 module into a PROFIBUS network may require an external gateway or connection module. Confirm the correct cables and gateways with your supplier before commissioning.

Maintenance and Reliability

Inspect the module periodically as part of routine panel checks. Verify the rotary switch has not been disturbed, confirm bus cabling is secure, and watch for heat buildup around the rack. Because the module is backplane-powered, there is no separate supply to service.

For spares planning, keep a known-good module on the shelf. A PROFIBUS slave failure can stop data exchange with the master, and fast dispatch, worldwide supply keeps that downtime short.

Selection Checklist

Before ordering, confirm your controller platform, the PROFIBUS DP master on the segment, and the required input/output byte count. Note that this is an Encompass third-party product, and lifecycle status is not published by Rockwell. Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Comparable third-party alternatives include the ProSoft MVI69-PDPS, ILX69-PBS, and Hilscher RIF 1769-DPS.

Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1769-DPS
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $244.00

Additional Information

Allen-Bradley 1769-DPS PROFIBUS DP slave module for CompactLogix and MicroLogix 1500. 9.6 kbps to 12 Mbps, station address 1-126 via rotary switch, up to 244 bytes input/output, backplane-powered at 5V DC, 131 x 40 x 86 mm, 0 to 60 C, CE/UL. Encompass third-party product; verify lifecycle status with Oil AutoTech.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (1769-DPS-1.pdf)