Why the 1762-IR4 Belongs in Your MicroLogix Panel

Temperature drift, noisy RTD signals, and a stalled production line—these are the problems the Allen-Bradley 1762-IR4 is built to solve. As a four-channel RTD and resistance input module for the MicroLogix 1100, 1200, and 1400 controllers, it turns raw resistance from temperature sensors into clean, usable data your PLC can act on. When you need spares without the wait, Oil AutoTech keeps fast-dispatch stock ready for oil, gas, and industrial automation teams.

Figure 1: Front view of the Allen-Bradley 1762-IR4 industrial automation component showing its physical design and enclosure.

What the 1762-IR4 Actually Does

The 1762-IR4 is an analog input module that interfaces Resistance Temperature Detectors and resistance-generating devices. It uses Delta-Sigma conversion to translate resistance into digital values, then stores them in registers your controller can read. Each of the four channels works independently, so you can mix sensor types across one module. The unit also performs both module and channel diagnostics, and a single diagnostic LED shows status and power to help you find faults quickly.

Technical Specifications

Specification Value
Manufacturer Rockwell Automation
Brand Allen-Bradley
Product Family MicroLogix
Inputs Four (4)
Converter Type Sigma-Delta
Heat Dissipation 1.5 Watts
Compatible Controllers MicroLogix 1100 / 1200 / 1400
Compatible Resistance Signals 0 to 150 Ohm, 0 to 500 Ohm, 0 to 1000 Ohm, 0 to 3000 Ohm
Input Filters 10 Hz, 50 Hz, 60 Hz, 250 Hz, 500 Hz, 1 kHz
Data Formats raw/proportional, engineering units x 1, engineering units x 10, scaled-for-PID, percent full scale
Dimensions 90 x 87 x 40 mm
Mounting DIN rail or panel mount

Figure 2: Technical layout and connection details for the Allen-Bradley 1762-IR4 industrial automation component.

RTD Compatibility That Covers Real Plants

The 1762-IR4 accepts a wide range of RTD types: 100 Ohm Platinum 385, 200 Ohm Platinum 385, 500 Ohm Platinum 385, 1000 Ohm Platinum 385, 100 Ohm Platinum 3916, 200 Ohm Platinum 3916, 500 Ohm Platinum 3916, 1000 Ohm Platinum 3916, 10 Ohm Copper 426, 120 Ohm Nickel 672, 120 Ohm Nickel 618, and 604 Ohm Nickel-Iron 518. It supports 2-wire, 3-wire, and 4-wire RTD connections, plus 2-wire and 3-wire resistance devices. That flexibility means one spare module can cover multiple sensor types across your plant—practical when you are standardizing spares for oil and gas skids or process lines.

Where It Fits in Oil, Gas, and Industrial Automation

In upstream oil and gas, RTDs monitor bearing temperatures on pumps and compressors. A failing input module can blind your control system to a hot bearing, risking unplanned downtime. The 1762-IR4 restores that visibility with four channels in a compact 90 x 87 x 40 mm housing. In food and beverage processing, the same module tracks pasteurization and CIP temperatures where accuracy matters. For general industrial automation, it can also monitor displacement on cylinders and clamping devices, giving you more use from one module.

Installation and Setup Notes

Mount the 1762-IR4 on a DIN rail or panel inside a clean, dry, non-hazardous enclosure away from electrical noise and heat. The module receives 5V and 24V DC power through the 1762 bus interface. A finger-safe cover protects the input terminal blocks. Configure each channel after installation, and remember that update time depends on your filter choice and autocalibration settings—fastest with one channel at 1 kHz, slowest with all channels at 10 Hz. Always follow your site’s safety procedures and verify program changes before troubleshooting.

Selection Checklist Before You Buy

Confirm your controller is a MicroLogix 1100, 1200, or 1400. Match your RTD type and wiring (2-wire, 3-wire, or 4-wire) to the module’s compatibility list. Check that your resistance signal falls within the supported ranges. If you need help matching the 1762-IR4 to your existing panel, the team at Oil AutoTech offers hands-on technical selection support. Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Frequently Asked Questions

Which controllers work with the 1762-IR4?

It is a compatible expansion module for MicroLogix 1100, 1200, and 1400 controllers. The number of modules you can use depends on the controller model.

Can I use 2-wire, 3-wire, and 4-wire RTDs on the same module?

Yes. The 1762-IR4 supports 2-wire, 3-wire, and 4-wire RTD connections, as well as 2-wire and 3-wire resistance devices.

How does the module handle noisy signals?

It offers input filters at 10 Hz, 50 Hz, 60 Hz, 250 Hz, 500 Hz, and 1 kHz. Choose a filter based on your update time and noise requirements.

What data formats can I use?

You can format data as raw/proportional, engineering units x 1, engineering units x 10, scaled-for-PID, or percent full scale.

How do I know if the module has a fault?

A single diagnostic LED indicates status and power, and the module performs both module and channel diagnostics to help identify problems.

Specifications

Model / No. 1762-IR4
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $256.00

Additional Information

The 1762-IR4 is an Allen-Bradley MicroLogix module with Four (4) channel RTD and Resistance input module. This input module is compatible for 100? Platinum 385, 200? Platinum 385, 500? Platinum 385 ,1000? Platinum 385, 100? Platinum 3916, 200? Platinum 3916, 500? Platinum 3916, 1000? Platinum 3916, 10? Copper 426, 120? Nickel 672, 120? Nickel 618 and 604? Nickel-Iron 518 RTD. It is also Technical specifications for 1762-IR4
Manufacturer Rockwell Automation
Brand Allen-Bradley
Function Resistance Module
Part Number/Catalog No. 1762-IR4
Converter Type Sigma-Delta
Product Family MicroLogix
Inputs 4
Heat Dissipation 1.5 Watts
Product Type RTD / Resistance Input Module
No. of Inputs Four (4)
UPC 10611320861676
Compatible RTD Sensors RTD Type 100? Platinum 385, 200? Platinum 385, 500? Platinum 385 , 1000? Platinum 385, 100? Platinum 3916, 200? Platinum 3916, 500? Platinum 3916, 1000? Platinum 3916, 10? Copper 426, 120? Nickel 672, 120? Nickel 618 and 604? Nickel-Iron 518 RTD, 2-Wire, 3-Wire, 4-Wire RTD
Compatible Resistance signals 0 to 150?, 0 to 500?, 0 to 1000? and 0 to 3000?
Compatible Controllers MicroLogix 1100 / 1200 / 1400
Data Formats raw/proportional, engineering units x 1, engineering units x 10, scaled- for-PID and percent full scale
Input Filters 10 Hz, 50 Hz, 60 Hz, 250 Hz, 500 Hz and 1 kHz
Resolution Input filter and configuration dependent.
Conversion Method Delta-Sigma Description
The Allen-Bradley 1762-IR4 is an Allen-Bradley analog input module that is specifically made to interface Resistance Temperature Detectors (RTD) and Resistance generating devices. This module is suitable for use in Temperature applications as RTD are instruments that measure temperature by generating a specific resistance output as a certain temperature. Additionally, this module may also be used to monitor displacement or measure displacement of devices. Devices such as cylinders, clamping devices and many others.

This module is compatible for a variety of RTD types. Specifically, compatible RTD sensors include 100? Platinum 385, 200? Platinum 385, 500? Platinum 385 ,1000? Platinum 385, 100? Platinum 3916, 200? Platinum 3916, 500? Platinum 3916, 1000? Platinum 3916, 10? Copper 426, 120? Nickel 672, 120? Nickel 618 and 604? Nickel-Iron 518 RTD. These RTDs may be 2-Wire, 3-Wire or 4-Wire RTDs. If used with resistance generating devices, this module accepts resistance ranges of 0 to 150?, 0 to 500?, 0 to 1000? and 0 to 3000?.

The received analog value from the individual channels is converted and saved to a register which may be formatted as raw/proportional, engineering units x 1, engineering units x 10, scaled-for-PID and percent full scale. Input filters may be used to filter noises for conditioning of the input signal.

This module is compatible expansion module of MicroLogix 1100, 1200 and 1400. The number of instance of this module depends on the MicroLogix controller used.

The 1762-IR4 is an Allen-Bradley MicroLogix expansion module. This module has Four (4) channel RTD/resistance input module. It enhances the functionality of MicroLogix 1100 / 1200 / 1400 controllers.

The 1762-IR4 has a dimension of 90 x 87 x 40 mm. The analog input data is converted via Delta-Sigma conversion. The module’s heat dissipation is 1.5 Watts and requires minimum mounting space. The module’ installation could be either DIN rail or panel mounted. It is compatible with various RTDs (Resistance Temperature Detectors) and Resistance devices. The 1762-IR4 module has a single diagnostic LED that indicates both status and power and helps identify the source of all problems. The module communicates and receives 5V and 24V DC power via the 1762 bus interface. It auto-calibrates on the channel enable but the user can also program it to calibrate every 5 minutes. For wiring the input terminal blocks, a finger-safe cover is present. The 1762-IR4 module can be connected to three types of RTDs i.e., 2-wire, 3-wire, and 4-wire and 2 types of resistance devices i.e. 2-wire and 3-wire. It uses 6 input words and 5 configuration words. The operation details must be configured for each channel after module installation. The module update time is fastest when only 1 input channel is connected to 1 kHz filter and slowest when all 6 input channels are connected to 10 Hz filter. With an increase in autocalibration and lead wire compensation cycles, the module update time also increases. For safety, while troubleshooting, always stands away from the equipment and always check for any program change. The safety circuits should always be wired in series to the master relay. It should be installed in non-hazardous, dry, and clean environments away from any electrical noise and heat. The 1762-IR4 module performs both module and channel diagnostics.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1746_1747_1762-IR4_Service_Manual)

Latest News

View All News