Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-OB8EI | Allen-Bradley ControlLogix 8-Point DC Output Module

  • Model 1756-OB8EI
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$284.00 Indicative price · request a quote for availability

Allen-Bradley 1756-OB8EI ControlLogix 8-point DC output module with electronically fused, individually isolated channels. Fast dispatch, worldwide.

Product Description

Why the 1756-OB8EI Belongs in Your ControlLogix Rack

Downtime in oil, gas, and industrial automation lines rarely comes from the controller. It comes from the I/O that drives the field. The Allen-Bradley 1756-OB8EI is a ControlLogix discrete output module built to keep those loads switching: eight electronically fused, individually isolated sourcing channels in a single slot.

Each channel delivers a nominal 24VDC output across a 10-30VDC range. That headroom matters when you are energizing relay coils, pilot lamps, horns, sirens, and solenoid valves on a busy skid. One channel fault does not take the card down, because isolation and electronic fusing are per point.

Figure 1: Front view of the Allen-Bradley 1756-OB8EI industrial automation component showing its physical design and enclosure.

Technical Specifications That Drive Cost Control

Current Ratings and Thermal Budget

The 1756-OB8EI carries 2 A per channel at 60 °C, with 10 A per module at 60 °C and 16 A at 55 °C on a linear derating curve. Power dissipation is 4.7 W at 60 °C. In a cabinet full of cards, that number sets your cooling load and your enclosure sizing. Plan the derating curve before you add channels, not after.

Backplane and Switching Behavior

Backplane draw is 250 mA at 5.1VDC and 2 mA at 24VDC, so the module is light on the chassis supply. Output signal delay is 1 ms maximum OFF to ON and 5 ms maximum ON to OFF. For most valve and relay duty, that is fast enough to keep cycle times tight without overspending on a specialty card.

Isolation and Diagnostics

Each point is individually isolated and electronically fused. The module supports configurable fault mode and program mode behavior, with last state, on, or off options. Default for both is off. That gives you a predictable safe response when the processor drops out of run.

Where This Module Earns Its Place

On a wellhead control panel, the 1756-OB8EI switches pilot lamps and valve solenoids while keeping each circuit isolated from the next. A fault on one solenoid does not cascade into the rest of the skid.

In a pipeline monitoring station, the 8-point density fits compact racks where panel space is expensive. Fewer cards mean fewer slots, less wiring, and lower installed cost per point.

On a factory floor running distributed I/O, the module works with any POINT I/O communication adapter, so you can push outputs closer to the machine and cut copper runs.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-OB8EI industrial automation component.

Installation and Compatibility Notes

The 1756-OB8EI installs in a single 1756 ControlLogix chassis slot and uses a removable terminal block, either 1756-TBCH or 1756-TBS6H. It is open-style with no enclosure rating, so it belongs inside a protected panel. Operating temperature is 0-60 °C, with non-operating range of -40-85 °C and 5-95% non-condensing humidity.

When integrating into a ControlLogix or distributed I/O network, confirm your adapter, cabling, and gateway requirements with your supplier before commissioning.

Selection Checklist Before You Buy

Verify your load current per point against the 2 A rating at 60 °C. Check total module current against the derating curve. Confirm you have the correct terminal block on hand. And confirm the lifecycle status and availability with Oil AutoTech before ordering.

Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-OB8EI
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $284.00

Additional Information

Mfr. Part Number:
1756-OB8EI
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen-Bradley 1756-OB8EI ControlLogix Fused Isolated Output 10-30V DC 8-Point, A
Full Description: Allen-Bradley 1756-OB8EI ControlLogix DC Electronically Fused Isolated Output Module, 10-30V DC, 8-Point, 36-Pin The Allen-Bradley 1756-OB8EI is a ControlLogix Discrete output module that features Eight (8) electronically fused, individually isolated non-isolated sourcing output channels. It has One (1) group of channels with Eight (8) outputs per channel. It delivers a nominal actuating voltage of 24VDC and compatible with any POINT IO communication adapter for implementing distributed I/O Technical specifications for 1756-OB8EI
Manufacturer Rockwell Automation
Module Type Digital DC Sourcing Output
Series ControlLogix
Part Number/Catalog No. 1756-OB8EI
Brand Allen-Bradley
No. of outputs Eight (8) Electronically-fused, individually isolated channels
Output Voltage 24VDC
Output Voltage range 10-30VDC
Output Current per channel, nom. 2 A @ 60 °C (140 °F)
Output Current per module, max. 10 A @ 60 °C (140 °F); 16 A @ 55 °C (131 °F) linear derating
Backplane Current, 5.1VDC 250 mA
Backplane Current, 24VDC 2 mA
Power Dissipation 4.7 W @ 60 °C (140 °F)
Output Signal delay, OFF to ON 1 ms, max
Output Signal delay, ON to OFF 5 ms max
Enclosure type rating None (open-style)
Removable Terminal Block 1756-TBCH; 1756-TBS6H
Outputs 8-Point Individually Isolated, Electronically Fused
Voltage 12-24 Volts DC
Operating Voltage Range 10-30 Volts DC
Maximum Output Current Rating-Point 2 Amps at 60 degrees Celsius
Maximum Output Current Rating-Module 16 Amps at 55 degrees Celsius, 10 Amps at 60 Celsius
Power Dissipation (Max) 4.7 Watts at 60 Celsius
Backplane Current at 5 Volts 250 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None Description
The Allen-Bradley 1756-OB8EI is a discrete output module from the ControlLogix product family. This module features Eight (8) electronically fused and individually isolated output channels that is able to deliver 24VDC nominal voltage output, with output voltage range of 10-30VDC. This module is generally used to energize electrical loads such as relay coils, pilot lamps, buzzer, horn, siren, valves and other actuating devices.

The 1756-OB8EI is directly installed to an available slot of the 1756 ControlLogix chassis. It occupies a single slot and permits multiple instances of the same module whether on a local or distributed I/O rack. It draws backplane current of 250 mA at 5.1VDC and 2 mA at 24VDC and consumes total backplane power of 1.30 W. This module has a power dissipation of 4.7 W when operated at 60 Deg. Celsius.

The 1756-OB8EI has an output current rating of 2 A @ 60 °C (140 °F) per point while the total current per module are 10 A @ 60 °C (140 °F) and 16 A @ 55 °C (131 °F), linear derating. It has a Surge current rating of 4 A for 10 ms each, repeatable every 2 s. The 1756-OB8EI has an OFF to ON delay time of 1 ms, maximum and ON to OFF delay time of 5 ms, maximum.

The 1756-OB8EI is used with a Removable Terminal Block (RTB) where signal wires are terminated. Compatible terminal blocks are 1756-TBCH and 1756-TBS6H.

This module has an operating voltage of 10-30V DC and a voltage category of 12-24V DC sink/source. It has a short trip of greater than 4.5 A for a maximum of 500 µs (output on, then short) and greater than 4.5 A for a maximum of 1.5 ms (output on into short), with a +/- 1 ms timestamp of diagnostics. It has a current draw of 250 mA at 5.1V and 2 mA at 24V. The module's total backplane power is 1.30 W with a maximum thermal dissipation of 16.03 BTU/hr. The module has a maximum off-state leakage current of 1 mA per point and a maximum voltage drop of 1.2V DC at 2 A. It also has a maximum current per point of 2A at 60 degrees Celsius and a maximum current per module of 10A at 60 Degrees Celsius and of 16A at 55 Degrees Celsius (linear derating). It has a surge current per-point of 4 A for 10 ms that is repeatable every 2s and with a 3 mA load current minimum. It also has a continuous isolation voltage of 250V and this module is routine-tested for 2s at 1350V. The 1756-OB8EI allows you the option of holding the last state and turning on or turning off the states in Fault Mode or Program Mode. Note that the default setting for both is “Off.” It also has an output delay time of a maximum of 1 m from off to on and a maximum of 5 ms from on to off. Its operating temperature has a range of 0-60 degrees Celsius, while its non-operating temperature has a range of -40-85 degrees Celsius. It also has a maximum surrounding air temperature of 60 degrees Celsius and a non-condensing relative humidity level of 5-95%.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-OB8EI_Service_Manual)

Latest News

View All News