Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-OB16D | Allen-Bradley ControlLogix 16-Point Diagnostic Output Module

  • Model 1756-OB16D
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$244.00 Indicative price · request a quote for availability

Allen-Bradley 1756-OB16D ControlLogix 16-point diagnostic DC output module with 19.2-30V DC range, per-point electronic fusing, and point-level diagnostics.

Product Description

What Makes the 1756-OB16D a Smart Choice for ControlLogix Systems?

Downtime on a production line rarely announces itself. It starts with a failed output point that no one saw coming. The Allen-Bradley 1756-OB16D ControlLogix diagnostic DC output module was built to close that gap. It combines 16 diagnostic outputs with point-level monitoring, so faults surface before they cascade into full stoppages.

This module belongs to the proven ControlLogix series from Allen-Bradley / Rockwell Automation. It operates on a 24V DC source voltage category with an operating voltage range of 19.2-30V DC. Each point is electronically fused, and the module supports configurable diagnostics including no-load detection, output verify detection, and diagnostic latching.

Figure 1: Front view of the Allen-Bradley 1756-OB16D industrial automation component showing its physical design and enclosure.

Key Technical Specifications

Specification Value
Outputs 16-point diagnostic
Voltage Category 24V DC source
Operating Voltage Range 19.2-30V DC
Max Output Current per Point 2 A at 30 °C
Max Output Current per Module 8 A at 30 °C / 4 A at 60 °C
Backplane Current at 5V 250 mA
Backplane Current at 24V 140 mA
Power Dissipation (Max) 3.3 W at 60 °C
Isolation Voltage 50V continuous
Removable Terminal Block 1756-TBCH or 1756-TBS6H

What the Specs Mean in Practice

The 2 A per-point rating at 30 °C gives you headroom for demanding DC loads without external relays in many cases. The linear derating to 1 A per point at 60 °C matters in cabinets where ambient heat builds. The 19.2-30V DC operating range tolerates the voltage sag common on long 24V DC distribution runs.

Diagnostic features set this module apart. No-load detection works in the off state, while output verification works in the on state. You can configure fault states per point, choose output behavior in Program mode, and latch diagnostics for later review. The short trip diagnostic function is 8 A for 180 ms minimum and 10 A for 120 ms minimum.

Where the 1756-OB16D Fits

Oil and Gas Skids

On remote wellhead skids, a failed output can mean a missed valve command. The 1756-OB16D reports point-level faults back to the controller, so operators see problems without sending a technician to site.

Water Treatment and Pump Control

Pump sequencing depends on reliable DC outputs. The 1 mA maximum off-state leakage current per point helps prevent false activation of sensitive pilot devices.

Packaging and Material Handling

High-cycle solenoid and indicator loads benefit from the 4 A surge current per point for 10 ms, repeatable every second. Electronic fusing per point limits damage from a single shorted field device.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-OB16D industrial automation component.

Installation and Integration Notes

Install the module in any available slot in a compatible ControlLogix chassis. A 36-position removable terminal block housing is required. Use either the 1756-TBCH or 1756-TBS6H. Ground the chassis and power supply before seating the module with its RTB.

Output delay times are fast: 55 µs nominal (1 ms maximum) from Off to On, and 630 µs nominal (5 ms maximum) from On to Off. These figures support responsive control loops.

If you plan to integrate this module into a networked ControlLogix architecture, confirm your cabling and any gateway or connection module requirements with your supplier before ordering.

Maintenance and Reliability

The operating temperature range is 0 to 60 °C, with storage from -40 to 85 °C. In practice, keep cabinet ambient below the derating threshold to preserve full current capacity. Inspect terminal block connections periodically and follow the manufacturer’s safety manual for all service work.

Isolation is rated 50V continuous. Group-to-group and user-to-system isolation were tested at 2546V for 1 second, with a 250V AC maximum continuous voltage.

Selection Checklist

Before ordering, confirm your chassis slot availability, your field device voltage, and your terminal block housing choice. Verify current lifecycle status and availability with Oil AutoTech before ordering. For spares when you need them, contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-OB16D
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $244.00

Additional Information

Mfr. Part Number:
1756-OB16D
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen-Bradley 1756-OB16D ControlLogix 19-30VDC Diagnostic Output Module 16-Point
Full Description: Allen-Bradley 1756-OB16D ControlLogix 19-30 VDC Diagnostic Output Module, 16 Points (36 Pin). Number of Outputs: 16 diagnostic; Voltage Category: 12/24V DC source; Operating Voltage: 19.2-30V DC; Removable Terminal Block Housing: 1756-TBCH or 1756-TBS6H. Allen-Bradley 1756-OB16D ControlLogix 19-30 VDC Diagnostic Output Module provides diagnostic features to the point level. Allen Bradley ControlLogix Diagnostic DC Output Module with 16-Point Diagnostic Outputs Technical specifications for 1756-OB16D
Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 1756-OB16D
Series ControlLogix
Module Type Diagnostic DC Output Module
Outputs 16-Point Diagnostic
Voltage 24 Volts DC Source
Operating Voltage Range 19.2-30 Volts DC
Maximum Output Current Rating-Point 2 Amps at
Maximum Output Current Rating-Module 8 Amps at 30 degrees Celsius and 4 Amps at 60 degrees Celsius
Power Dissipation (Max) 3.3 Watts at 60 Celsius
Backplane Current at 5 Volts 250 milliamps
Backplane Current at 24 Volts 140 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None
UPC 10612598164537 Description
The Allen-Bradley 1756-OB16D is a ControlLogix DC diagnostic output module. It has 16 diagnostic outputs available, with 8 points per group, and has been fused electronically on a per-point basis. You can install it in any available slot in a compatible ControlLogix chassis. However, a 36-position removable terminal block housing (RTB) is required for this. The RTB can either be the 1756-TBCH or the 1756-TBS6H. It is important to install and ground the chassis and power supply before installing the module with the RTB.

This 1756-OB16D module has the following features in common with other output modules: output data echo, multiple output point densities, configurable point-level output states, electronic fusing, and isolated and non-isolated varieties of output modules. It also allows you to configure various features of the module, particularly a no-load detection, output verify detection, output state in Fault mode, output state in Program mode, transition from Program state to Fault state, and diagnostic latching.

The short trip diagnostic function of the 1756-OB16D module is 8 A for 180 ms (minimum) and 10 A for 120 ms (minimum). The no-load function is only for off-state detection and the output verification is only for on-state detection. The pulse test has a user-configurable maximum pulse width. The module also allows you to configure Fault states per point and state in Program mode per point, where 'Off' is set by default and other options are 'On' and 'Hold Last State'.

This output module possesses an operational voltage range of 19.2 to 30V DC and a 24V DC source voltage category. It also has a 3 mA per point minimum load current, a 1 mA per point maximum off-state leakage current, and a 1.2V DC at 2 A maximum on-state voltage drop. Its backplane current is 140 mA at 24V DC and 250 mA at 5.1V DC and comes with a total backplane power of 4.64 W. Its linear derating output current rating is 2 A maximum at 30 Degrees Celsius (80 Degrees Fahrenheit) and 1 A maximum at 60 Degrees Celsius (140 Degrees Fahrenheit) for per-point and the rating is 8 A maximum at 30 Degrees Celsius and 4 A maximum at 60 Degrees Celsius for per-module. The surge current per point of the 1756-OB16D module is 4 A for 10 ms each, which is repeatable for every second. Its isolation voltage from group-to-group and user-to-system have been tested at 2546V for 1 s and both have a 250V AC maximum continuous voltage.

It has an output delay time of 55µs nominal and a maximum of 1 ms from Off to On and 630µs nominal and a maximum of 5 ms from On to Off. The operating temperature range is 0 to 60 Degrees Celsius (32 to 140 Fahrenheit) and the storage temperature is -40 to 85 Degrees Celsius (-40 to 185 Fahrenheit).

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-OB16D_Service_Manual)

Latest News

View All News