Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-L81E | Allen-Bradley ControlLogix 5580 Processor 3MB

  • Model 1756-L81E
  • Type PLC Controllers
  • Condition In Stock
4.6/5 (16 reviews)
$258.00 Indicative price · request a quote for availability

Allen-Bradley 1756-L81E ControlLogix 5580 processor with 3MB user memory, EtherNet/IP and USB. Ready-to-ship spares for oil, gas and automation.

Product Description

What Makes the Allen-Bradley 1756-L81E the Right Controller for Your Line?

Is your plant stuck waiting on a controller that can handle modern connectivity without a full platform overhaul? The Allen-Bradley 1756-L81E answers that question. It is a ControlLogix 5580 processor from Rockwell Automation, built as a single-slot controller for the 1756 chassis. With 3 MB of user memory and one embedded Ethernet port plus one USB port, it gives you a practical path for demanding industrial applications.

Figure 1: Front view of the Allen-Bradley 1756-L81E industrial automation component showing its physical design and enclosure.

Key Parameters That Matter on the Floor

The 1756-L81E carries 3 MB of user memory. That capacity suits control programs that need room for logic, routines and data without pushing into a larger controller class. The embedded Ethernet port communicates at 10 Mbps, 100 Mbps and 1000 Mbps, and the controller supports up to 60 EtherNet/IP devices. A USB 2.0 port at 12 Mbps handles local programming access.

Power figures are modest. Power dissipation is 6.2 Watts, current draw is 1.20 milliamperes at 5.1 Volts and 5.0 milliamperes at 1.2 Volts DC. Isolation voltage is 50 Volts continuous. The unit handles up to 128,000 digital I/O points and 4,000 analog I/O points.

Built for Oil, Gas and Process Uptime

In oil and gas, a controller often sits at the center of a skid, a compressor station or a pipeline segment. The 1756-L81E fits those roles because it supports simplex and redundant configurations. You can pair it with standard power supplies such as the 1756-PA75 or redundant supplies like the 1756-PA75R. That flexibility lets you design for availability where a stoppage costs real money.

For migration projects, the 1756-L81E also serves as a platform for moving legacy PLC-5 and SLC 500 logic into a modern environment. Instead of replacing every panel, engineers can standardize on ControlLogix and reuse existing field wiring.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-L81E industrial automation component.

Installation and Chassis Fit

The 1756-L81E installs in any slot of a compatible ControlLogix chassis and occupies a single slot. Supported chassis include the 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17 Series B and Series C frames. The enclosure is open-style, so plan for a proper panel or cabinet environment.

The operating temperature range is 0 to 60 degrees Celsius at 5 to 95 percent ambient humidity without condensation. The controller withstands 30G shock and 2G vibration at 10 to 500 Hz. It carries a T4 temperature code for ATEX, IECEx and North America, and holds IECEx, CSA and c-UL-us certifications with IEC 61000-6-4 rated emissions.

Integration and Programming

The 1756-L81E is supported in the Studio 5000 Automation Engineering and Design Environment. It offers 32 tasks with 1000 programs per task, and a 4 character alpha/numeric display for local status. When you wire into an EtherNet/IP network, confirm your cables and any gateway or connection module needs with your supplier before commissioning.

Before You Order

Verify your chassis model, power supply selection and whether you need simplex or redundant operation. If you need spares when you need them, Oil AutoTech offers fast dispatch, worldwide, plus hands-on technical selection help. Contact Oil AutoTech today for pricing and availability.

Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Specifications

Model / No. 1756-L81E
Product Type PLC Controllers
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $258.00

Additional Information

Mfr. Part Number:
1756-L81E
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen-Bradley 1756-L81E ControlLogix Logix5580 Processor, 3MB, EtherNet/USB
Full Description: Allen Bradley 1756-L81E ControlLogix5580 Logix 5580 Controller, 3MB User Memory, USB 2.0 Port (12 Mbps), 1GB Ethernet Port, 60 EtherNet/IP Devices, 32 Tasks, 1000 Programs/Task, 4 Character Alpha/Numeric Display, Supported in Studio 5000 Automation Engineering & Design Environment The 1756-L81E controller is one of the standard ControlLogix series industrial controllers that is designed and manufactured by Allen-Bradley/Rockwell Automation. It has 1 USB port and an embedded Ethernet port. The 1756-L81E standard controller can communicate on the Ethernet network at speeds of 10 Mbps, 100 Mbps, and 1000 Mbps. In addition to the Ethernet network, the 1756- Technical specifications for 1756-L81E
Manufacturer Rockwell Automation
Isolation Voltage 50 Volts Continuous
Power Dissipation 6.2 Watts
Current Draw (5.1 Volts) 1.20 Miliamperes
Current Draw (1.2 Volts DC) 5.0 Miliamperes
User Memory 3 MB
Module Type ControlLogix Controller
Part Number/Catalog No. 1756-L81E
Enclosure None (Open-Style)
Brand Allen-Bradley
Communication interfaces One (1) Ethernet; One (1) USB
Chassis 1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K,1756-A17, 1756-A17 K Series B, Series C
Standard Power Supply 1756-PA50, 1756-PA72, 1756-PA72K, 1756-PA75, 1756-PA75K, 1756-PB50, 1756-PB72, 1756-PB72K, 1756-PB75, 1756-PB75K, 1756-PH75, 1756-PC75
Redundant Power Supply 1756-PA75R, 1756-PA75RK, 1756-PB75R, 1756-PB75RK, 1756-PSCA2, 1756-PSCA2K
Series ControlLogix
I-O Memory N/A
Maximum I-O 128,000
Maximum Analog I-O 4,000
Maximum Digital I-O 128,000
Thermal Dissipation 21.2 BTU per hour Description
The Allen-Bradley 1756-L81E is a ControlLogix controller from the ControlLogix 5580 product family, the latest and modern designed ControlLogix series. It is a Programmable Automation Controller (PAC) that comes with modern connectivity and modern features allowing it to be used as migration platform for legacy controllers such as PLC5 and SLC500 controllers and solutions for demanding industrial application requirements.

The 1756-L81E lies in the low-end of the 1756-L8 series controllers as it only comes with a 3MB user memory and shipped with a 2GB non-volatile memory via the 1784-SD2 Secure Digital (SD) card. This controller is capable of handling a maximum number of 128,000 Discrete Input and Output signals and 4000 Analog Input and Output signals. It also eliminates the need of a battery to back-up the RAM of the controller as it is provided with the environmentally friendly energy storage solution.

This controller is a controller module that only requires a single slot in the chassis. It may be installed to a variety of ControlLogix chassis such as 1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K,1756-A17, 1756-A17 K Series B, Series C chassis. It is also capable of being configured in simplex and redundant or high-availability systems with compatibility to a wide variety of power supplies such as 1756-PA50, 1756-PA72, 1756-PA72K, 1756-PA75, 1756-PA75K, 1756-PB50, 1756-PB72, 1756-PB72K, 1756-PB75, 1756-PB75K, 1756-PH75, 1756-PC75 standard power supplies and 1756-PA75R, 1756-PA75RK, 1756-PB75R, 1756-PB75RK, 1756-PSCA2, 1756-PSCA2K redundant power supplies.

It has a built-in USB 2. It offers multiple communication options and supports a maximum of 60 Ethernet/IP nodes. The 1756-L81E is installed in any slot of the ControlLogix Chassis and occupies a single slot. It has a T4 (ATEX, IECx, and North America) temperature code and an open-style casing. Its operating temperature ranges between 0 Degree Celsius and 60 deg. Celsius (32 degree Fahrenheit and 140 Degree Fahrenheit) at 5-95% ambient humidity without condensation. The 1756-L81E is IECx, CSA, and c-UL-us certified, and it has an IEC 61000-6-4 rated emission. It is rated to withstand a shock of 30G and a vibration of 2G at 10-500Hz.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-L81E_Service_Manual)

Latest News

View All News