1756-IRT8I | Allen-Bradley ControlLogix 8-Channel Analog Input Module

  • Model 1756-IRT8I
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$261.00 Indicative price · request a quote for availability

Allen-Bradley 1756-IRT8I: 8 isolated RTD, thermocouple and millivolt input channels for ControlLogix. Fast dispatch, worldwide.

Product Description

When Eight Sensors, One Chassis, and No Room for Error Collide

A process engineer is commissioning a reactor skid. Eight temperature points must feed one ControlLogix chassis: six thermocouples on the vessel, two RTDs on the jacket. The old approach meant separate modules, extra power supplies, and a cabinet that keeps growing. The Allen-Bradley 1756-IRT8I solves that problem directly. It is an 8-point isolated combined temperature and millivolts-sensing input module for the ControlLogix system, built by Allen-Bradley/Rockwell Automation. Each channel works independently in RTD, thermocouple, or millivolt mode, so one module covers the whole skid.

Figure 1: Front view of the Allen-Bradley 1756-IRT8I industrial automation component showing its physical design and enclosure.

What the 1756-IRT8I Actually Does

The module converts sensor signals through a Sigma-Delta analog-to-digital method and stores results as IEEE 32-bit floating point data. That data feeds HMIs, SCADA systems, DCS platforms, and PID calculations without extra conditioning. Eight individually isolated channels mean a fault on one loop does not drag down its neighbors. Isolation is rated 250 Volts continuous. Two CJC sensors support thermocouple use, with local and remote CJC accuracy of +/- 0.3 degrees Celsius. Channels configured for thermocouple inputs perform lead resistance self-calibration when module power is cycled. The sampling rate follows the RPI value, since this module does not offer an RTS parameter.

Technical Specifications

Specification Value
Module Type Analog RTD / Thermocouple / Millivolt Module
Inputs 8 Isolated Channels
Input Range 1…500 Ohm; 2…1000 Ohm; 4…2000 Ohm; 8…4000 Ohm; -100…100 mV
Resolution 24 bits
Data Format IEEE 32-bit floating point
Isolation Voltage 250 Volts Continuous
Module Scan Time 1 ms
Power Dissipation (Maximum) 4.6 Watts
Thermal Dissipation 15.7 BTU per hour
RTD Excitation Current 600 microamps
Thermocouple Types B, C, D, E, J, K, N, R, S, T, TXK/XK (L)
Thermocouple Linearization ITS-90
Removable Terminal Blocks 1756-TBNH, 1756-TBS6H

Reading the Resolution Numbers

At 24-bit resolution, the module resolves 0…510 Ohm at 0.06 milliohms per count and -101…101 mV at 0.01 microvolts per count. In practice, that means tight temperature control loops stay tight. Supported RTDs include 100, 200, 500, and 1000 Ohm platinum (alpha=385 and alpha=3916), 120 Ohm nickel (alpha=672), 100, 120, 200, and 500 Ohm nickel (alpha=618), and 10 Ohm copper (alpha=427).

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-IRT8I industrial automation component.

Where It Fits in Oil, Gas, and Process Plants

In upstream oil and gas, the 1756-IRT8I monitors wellhead temperatures and compressor bearing RTDs from a single chassis slot. Refineries use the millivolt range for direct sensor signals where a transmitter would add cost and failure points. Power and chemical plants rely on the isolated channels to keep grounded and ungrounded sensors on the same module without cross-talk. The common thread: fewer modules, less panel space, and lower power supply demand.

Integration and Maintenance Notes

The module requires a 36-pin RTB, either the 1756-TBS6H or the 1756-TBCH. Open circuit detection times are 2 seconds for thermocouple and 3-wire RTD inputs, and 5 seconds for 4-wire RTD inputs. Note that no open circuit detection occurs when wires are simultaneously disconnected from the INx/RTD C and INx/RTD D terminals on the same channel. Noise rejection is 75 dB at 60 Hertz in normal mode. Inspect terminal blocks periodically and follow the manufacturer’s safety manual for all maintenance. Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Selection Checklist

Before buying, confirm your sensor types against the supported RTD and thermocouple list, verify your input range needs, and confirm the terminal block part number. Oil AutoTech offers hands-on technical selection help and fast-dispatch spares for oil, gas, and industrial automation. Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-IRT8I
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $261.00

Additional Information

Manufactured by Allen-Bradley/Rockwell Automation, the 1756-IRT8I is a high-resolution analog I/O module. Specifically, it is an 8-point isolated combined temperature and millivolts-sensing input module. The 1756-IRT8I module is a member of the ControlLogix system, and it requires a 36-pin RTB, or a detachable terminal block housing. This can be either the 1756-TBS6H or the 1756-TBCH. The Allen-Bradley 1756-IRT8I has 8 isolated channels for use in any combination of RTD or Thermocouple modes. The Allen-Bradley 1756-IRT8I ControlLogix RTD Thermocouple Input Module is equipped with 2 CJC sensors for thermocouple use, but they can be ordered separately. The accuracy of local CJC sensor is +/- 0.3 degrees Celsius, and this is the same as remote CJC sensor accuracy. The 1756-IRT8I module’s channel sampling rate is determined only by the RPI value since the 1756-IRT8I does not offer RTS parameter. Similarly, channels configured for the thermocouple inputs does lead resistance self-calibration if the module power is cycled.

Some of the properties of the 1756-IRT8I module are the notch filter, multiple module input ranges, digital filter, rate alarm, under-range/over-range detection, 10-ohm copper offset, process alarms, sensor offset, sensor types, wire off detection, synchronized sampling, temperature units, thermocouple wire length compensation, and the cold junction compensation. The 1756-IRT8I ControlLogix RTD Thermocouple Input Module features improved analog I/O modules, three 8-channel isolated designs as well as 12 and 16-channel non-isolated designs all with the enhanced functionality of the analog I/O. This module provides faster performance, is more accurate, and presents better resolution and cost savings than other analog I/O modules because there is less space needed in its chassis for extra modules and power supplies. The 1756-IRT8I is a ControlLogix analog input module. It has Eight (8) individually isolated channels compatible for Resistance Temperature Detector (RTD) and Thermocouple sensors. Compatible RTDs are 100, 200, 500, 1000 ? Platinum, alpha=385; 100, 200, 500, 1000 ? Platinum, alpha=3916; 120 ? Nickel, alpha=672; 100, 120, 200, 500 ? Nickel, alpha=618; and 10 ? Copper. Compatible Technical specifications for 1756-IRT8I
Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 1756-IRT8I
Series ControlLogix
Module Type Analog RTD / Thermocouple / milivolt Module
Inputs 8 Isolated Channels
No. of Inputs Eight (8) Point Isolated RTD / Thermocouple / milivolt
Current Draw (5.1 Volts) 200 milliamps
Compatible RTD Type 100, 200, 500, 1000 ? Platinum, alpha=385 100, 200, 500, 1000 ? Platinum, alpha=3916 120 ? Nickel, alpha=672 100, 120, 200, 500 ? Nickel, alpha=618 10 ? Copper, alpha=427
Current Draw (24 Volts) 150 milliamps
Compatible Thermocouple Types B, C, D, E, J, K, N, R, S, T, TXK/XK (L)
Power Dissipation (Maximum) 4.6 Watts
Resolution 24 bits 0…510 ?: 0.06 m?/count 0…1020 ?: 0.12 m?/count 0…2040 ?: 0.25 m?/count 0…4080 ?: 0.50 m?/count -101…101 mV: 0.01 ?V/count
Thermal Dissipation 15.7 BTU per hour
Input Range 1…500 ? 2…1000 ? 4…2000 ? 8…4000 ? -100…100 mV
Isolation Voltage 250 Volts Continuous
Module Scan Time 1 ms
Backplane Current at 24 Volts 2 milliamps
Data Format IEEE 32-bit floating point
Backplane Current (5Volts) 250 mA
UPC 10885630245420
Backplane Current (24 Volts) 150 mA
Power Dissipation (Max) 4.6 W
UNSPSC 32151705
Removable Terminal Blocks 1756-TBNH, 1756-TBS6H Description
The Allen-Bradley 1756-IRT8I module is a high-resolution analog I/O module. In particular, it is an Eight (8) point isolated temperature sensing module compatible with RTD, Thermocouple and millivolt signals. The module is part of the ControlLogix system and requires the 36-pin RTB or Removable Terminal Block (RTB). Compatible RTB are 1756-TBCH or the 1756-TBS6H. It has 2 CJC sensors for thermocouple use. The CJC sensor accuracy is +/- 0.3 degrees Celsius, The channel sampling rate of the module is only determined by the RPI value because the 1756-IRT8I does not offer the RTS parameter. Also, channels configured for thermocouple inputs perform a lead resistance self-calibration when the module power is cycled. Features of the 1756-IRT8I module include multiple module input ranges, a notch filter, under-range/over-range detection, a digital filter, process alarms, a rate alarm, a sensor offset, a 10-ohm copper offset, wire-off detection, temperature units, sensor types, thermocouple wire length compensation, synchronized sampling, and cold junction compensation. The 1756-IRT8I has multiple input ranges available, namely 1 to 500 Ohms, 2 to 1000 Ohms, 4 to 2000 Ohms, 8 to 4000 Ohms, and -100 to 100 millivolts. It supports 24-bit resolution with ranges of 0 to 510 Ohms with 0.06 milliohms per count, 0 to 1020 Ohms with 0.12 milliohms per count, 0 to 2040 Ohms with 0.25 milliohms per count, 0 to 4080 Ohms with 0.50 milliohms per count, and -101 to 101 millivolts with 0.01 microvolts per count. RTD sensors that are supported include 100, 200, 500, 1000 Ohm platinum, alpha=385, 100, 200, 500, 1000 Ohms platinum, alpha=3916, 120 Ohms nickel, alpha 672, 100, 120, 200, 500 Ohm nickel, alpha=618, and 10 Ohm copper, alpha=427. The RTD excitation current of the module is 600 microamps. The thermocouple types for this module are B, C, D, E, J, K, N, R, S, T, and TXK/XK (L). Its thermocouple linearization is ITS-90. The module has open circuit detection times of 2 seconds for a thermocouple input and 3-wire RTD input and of 5 seconds for a 4-wire RTD input. It should be noted that there is no open circuit detection when wires are simultaneously disconnected from the INx/RTD C and INx/RTD D terminals on the same channel (with x representing the channel number). Noise rejections are available for the module. At normal mode, it is 75 dB at 60 Hertz. During common mode, it is 125 dB at 60 Hertz 1000 Ohms differential, 120 dB at 50 Hertz 1000 Ohms differential, and 160 dB at 600 Volts 100 Ohms differential.

The Allen-Bradley 1756-IRT8I is a ControlLogix analog input module with Eight (8) channels configurable for Resistance Temperature Detector (RTD), Thermocouple and millivolt input.

This module features high resolution analog to digital conversion via Sigma-Delta method. The converted data is saved to IEEE 32-bit floating point. The converted data are ideally accessed by Human Machine Interface (HMI), Supervisory Control and Data Acquisition (SCADA) and Distributed Control Systems (DCS). Other than computer-based systems, the signal data may be used for calculations, and Process Variables (PV) for controllers such as Proportional + Integral + Derivative (PID).

This module is capable of Open Circuit Detection with detection time of 2 Seconds for Thermocouple input and 3-Wire RTD and 5 Seconds for 4-Wire RTD.

Supported input range of this module are 1 - 500 ?, 2 - 1000 ?, 4 - 2000 ?, 8 - 4000 ? and -100 to 100 mV. The modules overall resolution is 24 Bits. With actual resolution of 0…510 ?: 0.06 m?/count 0…1020 ?: 0.12 m?/count 0…2040 ?: 0.25 m?/count 0…4080 ?: 0.50 m?/count -101…101 mV: 0.01 ?V/count.

Supported Thermocouple types include Thermocouple Type B, C, D, E, J, K, N, R, S, T, TXK/XK (L) with linearization of ITS-90. Compatible RTD sensors include 100 ? PT 385, 20 ? PT 385, 500 ? PT 385, 1000 ? PT 385, 100 ? PT 3916, 20 ? PT 3916, 500 ? PT 3916, 1000 ? PT 3916, 10 ? CU 427, 120 ? NI 672, 100 ? NI 618, 120 ? NI 618, 200 ? NI 618 and 200 ? NI 618. Compatible millivolt signals should be within the range of -100 to 100 mV.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-IRT8I_Service_Manual)

Latest News

View All News