Product Overview
When dynamic pressure monitoring demands reliability in extreme heat, the 143-216-000-011 from Vibro Meter delivers. This CP 216 piezoelectric pressure transducer operates from −70 to 520°C and handles pressures up to 350 bar. Maintenance engineers choose it for gas turbine testing and long-term monitoring where failure is not an option.

Technical Specifications
The CP 216 uses a compression-mode piezoelectric design with 200 pC/bar sensitivity. Its frequency response spans 2 Hz to 15 kHz with ±5% accuracy. The dynamic measuring range covers 0.0005 bar to 250 bar, with spike overload capacity to 350 bar. Linearity stays within ±1% across the full range.
The transducer features internal case insulation and a 2-pole system isolated from the casing. It requires no input power, generating a charge output directly. The mineral insulated cable uses twin conductors and can terminate with either a LEMO connector or a Vibro-Meter high-temperature connector.
Applications in Demanding Environments
Gas turbine monitoring represents the primary use case. The CP 216 thrives where combustion dynamics and pressure fluctuations must be tracked continuously. Its −70 to 520°C range covers extreme applications, while the standard continuous range of −54 to 470°C suits most turbine operations.
In industrial automation, this transducer supports development testing and long-term monitoring. The hermetically welded NIMONIC alloy 90 construction resists corrosion and humidity. Radiation tolerance includes gamma flux at 1010 erg/g and neutron flux at 1017 n/cm² with no effect.

Installation and Integration
The 143-216-000-011 connects to an IPC 704 signal conditioner through available cable assemblies. The charge output requires a charge converter for signal processing. Cable capacitance adds 200 pF/m pole-to-pole and 300 pF/m pole-to-casing.
Mounting follows standard compression-mode practices. The transducer weighs just 12 g, while the cable adds 25 g/m. Shock acceleration tolerance reaches 2000 g peak along the sensitive axis. For explosive atmospheres, the unit carries certification for use in potentially explosive environments.
Maintenance and Reliability
Factory calibration at 1 bar peak and 2 Hz means no subsequent calibration is necessary. The mineral insulated cable protects signal integrity in harsh conditions. Internal insulation resistance exceeds 109 Ω, maintaining performance at 450°C.
Periodic inspection of cable terminations and connectors ensures reliable operation. The LEMO connector handles −55 to 155°C, while the Vibro-Meter high-temperature connector extends to 650°C. Choose the connector based on your temperature profile.
Oil AutoTech supplies the 143-216-000-011 with fast dispatch, worldwide. Our team offers hands-on technical selection help to match the right connector and cable length to your application. Contact Oil AutoTech today for pricing and availability.
Please verify current lifecycle status and availability with Oil AutoTech before ordering.