Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1756-PAR2 | Allen-Bradley ControlLogix Redundant Power Supply Kit

  • Model 1756-PAR2
  • Type Power Supplies
  • Condition In Stock
4.6/5 (16 reviews)
$299.00 Indicative price · request a quote for availability

Allen-Bradley 1756-PAR2 ControlLogix redundant power supply kit with two 1756-PA75R supplies, CPR2 cables, and PSCA2 adapter for critical uptime.

Product Description

Product Overview

Downtime in a critical process cell rarely announces itself. It arrives when a single power supply drops out and takes an entire ControlLogix chassis with it. The Allen-Bradley 1756-PAR2 is built to remove that single point of failure. This is a complete ControlLogix redundant power supply kit from Rockwell Automation, bundling everything needed to feed one chassis from two independent supplies.

The kit contains two 1756-PA75R power supplies, two 1756-CPR2 cables, and one 1756-PSCA2 chassis adapter module. Rather than sourcing each piece separately, engineers receive a matched assembly ready for installation.

Figure 1: Front view of the Allen-Bradley 1756-PAR2 industrial automation component showing its physical design and enclosure.

What the 1756-PAR2 Kit Includes

Each element plays a defined role in the redundant architecture. The 1756-PA75R units accept 85-264VAC input and deliver up to 75 W of output power at 0…60 °C. Current capacity is distributed across the backplane rails: 1.5 A at 1.2VDC, 4 A at 3.3VDC, 13 A at 5.1VDC, and 2.8 A at 24VDC.

The 1756-CPR2 cables connect both supplies for synchronization and internal communication. Each cable measures 0.91 m (3 ft) with a minimum bend radius of 12.7 cm (5 in). The 1756-PSCA2 is a passive chassis adapter that consolidates power from both supplies into the single connector on the ControlLogix backplane.

Technical Specifications

Specification Value
Module Type Redundant Power Supply bundle
Series ControlLogix
Input Voltage Range 85-264VAC
Nominal Input Voltage 120/240VAC
Output Power 75 W @ 0…60 °C
Current Capacity 1.5 A @ 1.2VDC; 4 A @ 3.3VDC; 13 A @ 5.1VDC; 2.8 A @ 24VDC
Isolation Voltage 250V continuous, reinforced insulation
Max Inrush Current 20 Amperes
Hold Up Time 2 cycles @ 60 Hz; 2 cycles @ 50 Hz
Chassis Compatibility 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17

Where Redundant Power Pays Off

Continuous process industries feel power faults hardest. On an oil and gas skid, a supply failure can interrupt safety logic and force an unplanned shutdown. The 1756-PAR2 keeps the chassis energized through the second supply while maintenance responds.

Water treatment and pipeline monitoring stations face similar exposure. Remote cabinets often sit far from service crews, so a failed supply means hours of lost production. Redundant power converts a hard stop into a manageable event.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-PAR2 industrial automation component.

Installation and Setup

Mount a standard power supply at the left end of the chassis and fasten it directly to the backplane. Route the 1756-CPR2 cables between the two 1756-PA75R units to synchronize them, then connect the 1756-PSCA2 adapter so both supplies feed the chassis backplane. Verify that the chassis model matches the compatibility list before starting.

Sourcing and Support

Redundant power kits are often ordered under time pressure, and missing a single cable can stall a startup. Oil AutoTech supplies ready-to-ship ControlLogix spares with fast dispatch, worldwide. If you need selection help matching the kit to your chassis, the team can confirm compatibility before you commit.

Contact Oil AutoTech today for pricing and availability.

Please verify current lifecycle status and availability with Oil AutoTech before ordering.

Specifications

Model / No. 1756-PAR2
Product Type Power Supplies
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $299.00

Additional Information

Mfr. Part Number:
1756-PAR2
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen-Bradley 1756-PAR2 ControlLogix 85-265VAC Redundant Power Supply Kit
Full Description: Allen Bradley 1756-PAR2 ControlLogix 85-265V AC Redundant Power Supply Assembly, Contains: 2x 1756-PA75R Power Supplies, 2x 1756-CPR2 Cables, 1x 1756-PSCA2 Chassis Adapter The Allen-Bradley 1756-PAR2 is a ControlLogix Redundant Power Supply kit. This assembly is composed of Two (2) 1756-PA75R power supplies, Two (2) 1756-CPR2 cables and One (1) 1756-PSCA2 Chassis adapter module. Technical specifications for 1756-PAR2
Manufacturer Rockwell Automation
Module Type Redundant Power Supply bundle
Series ControlLogix
Part Number/Catalog No. 1756-PAR2
Brand 1756-PAR2
Assembly components Two (2) 1756-PA75R power supplies,; Two (2) 1756-CPR2 cables; One (1) 1756-PSCA2 Chassis adapter module
1756-PA75R Nom Input Voltage 120/240VAC
1756-PA75R Input Voltage Range 85-264VAC
Isolation Voltage 250V (continuous), Reinforced Insulation Type, Power Input to Backplane, Power Input to Annunciator, Annunciator to Backplane Type tested at 3250V DC for 60 s
Max Inrush Current 20 Amperes
Current Capacity 1.5 A at 1.2VDC; 4A at 3.3VDC; 13 A at 5.1VDC and 2.8 A at 24VDC
Output Power 75 W @ 0…60 °C (32…140 °F)
Annunciator Power 240V AC 50/60 Hz, 240V DC, 50 mA, resistive only
Hold Up time 2 cycles @ 60 Hz; 2 cycles @ 50 Hz
Chassis Compatibility 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Input Voltage 85-265 VAC Description
The Allen-Bradley 1756-PAR2 is a bundled system composed of products that belongs to the ControlLogix product family. The 1756-PAR2 is composed of Two (2) 1756-PA75R power supplies, Two (2) 1756-CPR2 cables and One (1) 1756-PSCA2 Chassis adapter module.

The 1756-PA75R is a redundant power supply use along another power redundant unit. This type of power supply provides failsafe protection and ideally used in critical application that require minimized risks of application downtime. The has an input voltage range of 85-264VAC, 47-63 Hz with nominal input voltage of 120 / 240 VAC along an nominal input frequency of 50/60 Hz. This power supply provides maximum output power of 75 Watts and current capacities of 1.5 @ 1.2 VDC; 4 A @ 3.3 VDC; 13 A @ 5.1 VDC and 2.8 A @ 24VDC. The 1756-CPR2 is a redundant power supply cable that is used to connect both the power supplies for synchronization and perform internal communication. This cable measures 0.91 m or 3 ft with minimum cable bend radius of 12.7 cm or 5 inches.

The 1756-PSCA2 is a ControlLogix redundant power supply chassis adapter. This component is a passive device, used to consolidate power from both the installed pair of power supplies to the lone power connector that resides on the ControlLogix chassis backplane circuitry.

This assembly provides user and control system designers to easily decide on the components of a redundant ControlLogix controller system configuration. It lessens the risk of having an item left-out which may happen when selecting large or complex control systems.

To set up the 1756-PAR2 power supply, attach a standard power supply to the left end of the framework and fasten it directly to the backplane. This unit is built with smart and rugged technology, giving the 1756-PAR2 ControlLogix-XT power supply the ability to withstand extreme temperatures and tough environments. A redundant power supply system provides extra uptime protection for chassis that are used in critical applications; it funnels power through the chassis adapter to the ControlLogix series B chassis backplane. To build a redundant power supply system, a redundant power supply system that offers additional protection for the framework being used in significant applications is required. The power supply directs the power through the framework adaptor to the ControlLogix series B framework backplane. To create a redundant power supply structure, some of the main components that are needed include a pair of bundled systems with one of them containing two 1756-PA75R power supplies, two 1756-CPR2 cables, and one 1756-PSCA2 framework adapter and other one having two 1756-PB75R power supplies, two 1756-CPR2 cables, and one 1756-PSCA2 framework adapter, in addition to a redundant AC power supply, a redundant DC power supply, a redundant power supply cable (with a length of 0.91 meters or 3 feet), a redundant power supply framework adapter, and an annunciator wiring (1) with a maximum length of 10 meters or 32.8 feet.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-PAR2_Service_Manual)

Latest News

View All News