  • Model 1756-IF8
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$229.00 Indicative price · request a quote for availability

Allen-Bradley 1756-IF8 ControlLogix analog input module with 8 configurable voltage/current channels, 15-16 bit resolution, and Sigma-Delta conversion.

Product Description

Product Overview

Downtime in a ControlLogix line rarely comes from the controller. It comes from the I/O layer, where analog signals from transmitters, transducers, and panel meters must be converted cleanly before the processor can act. The Allen-Bradley 1756-IF8 is a single-slot analog input module built for exactly that job. It belongs to the ControlLogix PAC family from Allen-Bradley / Rockwell Automation and provides Eight (8) input channels configurable for voltage or current signals.

For plants running continuous process loops, the cost of an unplanned stoppage dwarfs the price of the card itself. That is why sourcing a ready-to-ship replacement matters more than saving a few dollars on a slow channel.

Figure 1: Front view of the Allen-Bradley 1756-IF8 industrial automation component showing its physical design and enclosure.

Key Parameters and What They Cost You

The 1756-IF8 accepts -10…10V, 0…10V, 0…5V, and 0…20 mA input signals. That flexibility means one spare can cover multiple loop types across a facility, reducing the number of distinct cards you must stock. Fewer stocked variants translates directly into lower inventory carrying cost.

Resolution varies by range: ±10.25V delivers 320 µV/count (15 bits plus sign bipolar), 0…10.25V delivers 160 µV/count (16 bits), 0…5.125V delivers 80 µV/count (16 bits), and 0…20.5 mA delivers 0.32 µA/count (16 bits). Higher resolution on the lower ranges means tighter control of pressure, flow, and level loops, which reduces giveaway and rework.

Conversion uses the Sigma-Delta method, storing data in Integer mode (left justified, 2 s complement) or IEEE 32-bit floating point. The module draws 150 mA from the 5V backplane and 40 mA from the 24V backplane. Maximum power dissipation is 1.73 W in voltage mode and 2.33 W in current mode.

Scan time depends on wiring: 16-488 ms for single-ended, 8-244 ms for 4-point differential, and 5-122 ms for 2-point differential inputs. Faster scan on differential wiring can shorten control response time on fast loops.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-IF8 industrial automation component.

Wiring Options and Application Fit

The 1756-IF8 supports single-ended, differential, and high-speed differential wiring. Single-ended wiring ties all input devices to a common ground and maximizes usable channels. Choose differential wiring when signal pairs are separate, common ground is unavailable, or the environment demands better noise immunity. High-speed mode differential wiring gives the fastest data updates but uses only one out of every four channels.

Typical applications include interfacing transmitters, transducers, signal splitters, signal isolators, and panel meters. Built-in features such as the module filter, under-range/over-range detection, process alarms, wire off detection, and rate alarms help catch faults before they become scrap.

Integration and Sourcing Notes

The module uses removable terminal blocks 1756-TBCH and 1756-TBS6H with user-defined mechanical keying. It installs in a local chassis alongside the controller or in distributed I/O racks. Most ControlLogix controllers support up to 4000 analog I/O signals, so scaling is rarely a constraint.

Integration Note: wiring into fieldbus networks may require an external gateway or connection module. Confirm cables and gateways with your supplier before commissioning.

Please verify current lifecycle status and availability with Oil AutoTech before ordering. Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-IF8
Product Type I/O Modules
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $229.00

Additional Information

Mfr. Part Number:
1756-IF8
Manufacturer: Allen-Bradley / Rockwell Automation
Description: Allen Bradley 1756-IF8 ControlLogix Analog Input Module Current/Voltage 8-Points
Full Description: Allen Bradley 1756-IF8 ControlLogix Analog Input Module, Current/Voltage, 8 Points (36 Pin) The Allen-Bradley 1756-IF8 is an analog input module from the ControlLogix product family. This module features Eight (8) single-ended, differential and Two high-speed differential input channels, configurable for +/-10VDC, 0-10VDC, 0-5VDC and 0-20 mA input signals with resolution of 15 bits for +/-10VDC and 16 bits for other signal types. Technical specifications for 1756-IF8
Manufacturer Rockwell Automation
Backplane Current (24Volts) 40 mA
Power Dissipation (Max) Voltage mode: 1.73 W Current mode: 2.33 W
Backplane Current (5Volts) 150 mA
Module Type Analog Input
Series ControlLogix
Part Number/Catalog No. 1756-IF8
Brand Allen-Bradley
No. of Inputs 8- channel Voltage / Current inputs
Conversion Method Sigma-Delta
Data format Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Input signal Range -10…10V 0…10V 0…5V 0…20 mA
Input Resolution ±10.25V: 320 µV/count (15 bits plus sign bipolar) 0…10.25V: 160 µV/count (16 bits) 0…5.125V: 80 µ/V count (16 bits) 0…20.5mA: 0.32 µA/count (16 bits)
Inputs 2 high-speed differential, 4 differential, 8 single-ended
Input Resolution (+--) 10.25 Volts, 0-5.125 Volts, 0-10.25 Volts
Removeable Terminal Blocks 1756-TBCH, 1756-TBS6H
Power Consumption 1.73 Watts
UPC 10612598171795
UNSPSC 32151705 Description
The Allen-Bradley 1756-IF8 is an analog input module from the ControlLogix Programmable Automation Controller (PAC) family. This analog input module features Eight (8) input channels that are configurable for a variety of input signals such as +/-10VDC, 0-10VDC and 0-5VDC Voltage signals and 0-20 mA Current signals. This module is typically used to interface analog signal generating instruments and devices such as transmitters, transducers, signal splitters, signal isolators, panel meters and other similarly capable devices. The 1756-IF8 is a single slot module with a high-resolution of conversion. It has varying resolution, from 15-bit to 16-bit. Specific module resolution is ±10.25V: 320 µV/count (15 bits plus sign bipolar) for +/-10VDC, 160 µV/count (16 bits); for 0-10VDC, 80 µ/V count (16 bits); for 0-5VDC and 0…20.5mA: 0.32 µA/count (16 bits) for 0-20 mA signals.

There is virtually no limit to the number of installation instances of this module. Most ControlLogix controllers are capable of up to 4000 analog I/O signals. The 1756-IF8 may be installed in the local chassis along the controller or within distributed I/O racks.

The 1756-IF8 used the Sigma-Delta conversion method and saves received signal in Integer mode (left justified, 2 s complement) IEEE 32-bit floating point register. It uses 1756-TBCH and 1756-TBSH removable terminal block (RTB) with user defined, mechanical keying.

The module scan time also varies depending on the wiring configuration. For single eneded wiring, scan time is 16-488 ms, for 4 point differential, scan time is 8-244 ms while 5-122 ms for 2 point differential inputs.

The 1756-IF8 can be wired in three different ways: single-ended wiring, differential wiring, and high-speed mode differential wiring. In single-ended wiring, all the input devices are tied to a common ground and it allows the comparison of one side of the signal input to the signal ground. The difference is then used by the module in generating digital data for the controller. Using the single-ended wiring method maximizes the number of the module’s usable channels. You should use differential wiring when your applications can have separate signal pairs or common ground is unavailable and when you need improved noise immunity in your environment. Channels in this wiring method are not totally isolated from each other. But when you need the fastest data updates possible, you should use the high-speed mode differential wiring method. Note that this mode only allows the use of one out of every four channels on the module. Specific features of the 1756-IF8 include the module filter, under-range/over-range detection, process alarms, wire off detection, multiple input ranges, real-time sampling, digital filter, and rate alarms. Its backplane voltage and current ratings are 5.1 Volts DC, 150 milliamps maximum, 24 Volts DC, and 40 milliamps maximum. It has an input current range of 4 to 20 milliamps and an input voltage range of -10 to 10 Volts. Power consumption is 1.73 Watts and the maximum overvoltage protection is 30 Volts DC (voltage) and 8 Volts DC (current).

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1756_1756-IF8_Service_Manual)

Latest News

View All News