Room 7A, No. 59 Hubin North Road, Siming District, Xiamen City, China sales@oilautotech.com +86 181 5089 9927

Allen-Bradley

1747-L553 | Allen-Bradley SLC 5/05 CPU, 64KB Ethernet PLC

  • Model 1747-L553
  • Type PLC Controllers
  • Condition In Stock
4.6/5 (16 reviews)
$210.00 Indicative price · request a quote for availability

Allen-Bradley 1747-L553 SLC 5/05 processor with 64KB battery-backed RAM, Ethernet and RS-232. Ready-to-ship for oil, gas and industrial automation.

Product Description

Why the 1747-L553 Still Earns Its Slot

Downtime on an SLC 500 line rarely waits for a purchase order. When a processor fails, the whole cell stops, and every hour carries a cost. The Allen-Bradley 1747-L553 is the SLC 5/05 CPU that keeps medium-to-large discrete and analog operations running, and it remains one of the most requested spares in oil, gas and general factory automation.

This module is the highest-memory processor in the SLC 5/05 family, so it suits applications that outgrew smaller controllers without a full platform migration.

Figure 1: Front view of the Allen-Bradley 1747-L553 industrial automation component showing its physical design and enclosure.

What the 1747-L553 Actually Delivers

Memory and Program Capacity

The 1747-L553 carries up to 64 KB of battery-backed RAM, supported by the 1747-BA battery, with 64,000 words of user memory. Flash backup preserves logic through power events. For plants running long ladder programs with floating-point math and real-time clock functions, that headroom matters.

Scan Speed and I/O

Program scan time is 0.9 ms/K, and I/O scan time is 0.225 milliseconds. The processor supports up to 4096 inputs, 4096 outputs and 480 analog I/O points, across a maximum of 3 local I/O chassis with 30 module slots each. Bit-instruction execution runs at 0.37 milliseconds.

Communications

An integrated Ethernet channel handles 10/100 Mbps transmission over distances of at least 100 meters, and an RS-232 port supports peer-to-peer links to HMIs and programming workstations. Both ports can run simultaneously without affecting logic execution.

Environment

Operating temperature is 0 to 60 degrees Celsius, with 30G operating shock. Backplane current draw is 1 Amp at 5 Volts DC and 0 Amps at 24 Volts DC.

Comparison: 1747-L553 vs Other SLC 5/05 CPUs

Feature 1747-L553 Lower-memory SLC 5/05 CPUs
User memory 64,000 words Reduced capacity
Ethernet Integrated 10/100 Mbps Varies by model
RS-232 Yes Yes
Max local I/O chassis 3 Fewer or equal
Analog I/O 480 points Lower counts

If your program is pushing the limits of a smaller processor, the 1747-L553 removes that ceiling without changing chassis or wiring.

Figure 2: Technical layout and connection details for the Allen-Bradley 1747-L553 industrial automation component.

Where It Fits on Site

Oil and gas processing. The Ethernet port reaches remote panels across long cable runs, so a single processor can serve SCADA-style data collection while local RS-232 handles the HMI.

Factory automation. With 4096 inputs and 4096 outputs available, the controller manages mixed discrete and analog loops, from manual override through fully automatic sequencing.

Motion and position control. The PLC-5-derived instruction set supports complex control techniques, including messaging to PLC 5, CompactLogix and ControlLogix platforms.

Integration Notes

The 1747-L553 installs in any SLC 500 chassis with a fixed slot assignment of slot 0. Remote I/O, Data Highway Plus, DeviceNet and DH485 communication adapters can be added when the application requires them. The RS-232 port can be configured for a 1761-NET-AIC converter. When wiring into these networks, an external gateway or connection module may be required, so confirm cables and gateways with your supplier before commissioning.

Keeping the Processor Reliable

Inspect the 1747-BA battery on a scheduled basis and replace it during planned outages, since battery-backed RAM depends on it. Keep the enclosure clean and dry, and respect the 0 to 60 degrees Celsius ambient limit. Follow the manufacturer’s safety manual for all maintenance work.

Before You Order

Confirm your chassis slot layout, required communication adapters and memory needs. Please verify current lifecycle status and availability with Oil AutoTech before ordering. As a supplier focused on fast-dispatch spares for oil, gas and industrial automation, Oil AutoTech offers quick worldwide delivery and hands-on technical selection help. Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1747-L553
Product Type PLC Controllers
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $210.00

Additional Information

The Allen-Bradley/Rockwell Automation 1747-L553 module is a CPU or Central Processor Unit module from the Allen-Bradley SLC 500 and SLC 5/05 series. This CPU has CMOS RAM built into it that supports battery backup, and it can also support an Allen-Bradley 1747-M13 memory module that provides it with 64 K of additional memory. The 1747-L553 CPU module has an Ethernet channel. Technical specifications for 1747-L553
Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 1747-L553
Series SLC 500
Inputs 4096
Module Type SLC 5/05 Processor
Outputs 4096
Analog I/O 480
Memory: Up to 64 KB, Battery Backed-RAM
Program Scan Time 0.9 ms/K
User Memory 64,000 Words
I/O Chassis 3
Chassis Module Slots 30
I/O Scan Time 0.225 milliseconds
Communication Ethernet, RS-232
Backup Memory 1747-M13
Ambient Temperature 0 to 60 degrees Celsius
Battery back-up memory: Yes; 1747-BA
UPC 10662072745622
UNSPSC 32151705 Description
The 1747-L553 is an SLC 5/05 processor that belongs to the SLC 500 Programmable Logic Controller (PLC) platform. This controller has the highest memory among the SLC 5/05 category which is 64 KB memory. It has integrated RS32 Sub-D 9-Pin connector for establishing peer-to-peer communication with locally installed Human Machine Interface (HMI) or a programming workstation. It also has an integrated Ethernet that is ideally used for communication over a long distance, minimum of 100 meters at 10/100 mbps transmission speed. It is also ideal for establishing connection to multiple devices at a time. These Two (2) port may also be used simultaneously without affecting the processor’s logic execution capability.

This controller is ideal for medium to large scale application, with control requirements ranging from manual to automatic control of Discrete or analog loops as well as implementing complex control techniques with the utilization of a wide number of embedded instructions. It may be used in Factory automation, Process Automation even in motion and position control requirements.

It is also capable of sending Messages to other Allen-Bradley PLC platforms such as PLC 5, CompactLogix and ControlLogix via a specified communication protocol. Though integrated with Ethernet and RS232 ports, this processor may be installed with communication adapters such as Remote I/O (RIO), Data Highway Plus (DH+), DeviceNet and DH485.

It may be installed to any SLC 500 chassis. This processor module has a fixed slot assignment of slot Zero (0).

It contains a PLC-5 processor-based advanced instruction set. The 1747-L553 can stand alone or be distributed throughout the system for SCADA applications. The 1747-L553 processor has a total user memory of 64K words with 60K words for data/program and 4K words for just data. It has up to 4096 inputs, 4096 outputs, and 480 local analog I/O. It has a program scan time per keyword of 0.9ms and 0.225 milliseconds I/O scan time. The 1747-L553 has a backplane current of 1 Amp at 5 Volts DC and 0 Amps at 24 Volts DC. It has a maximum of 3 local I/O chassis with maximum 30 module I/O slots in local I/O chassis.

For communication, it uses Ethernet and RS-232 ports that can be configured for connection to the 1761-NET-AIC converter. It has standard battery-backed RAM and Flash backup memory. With this processor, Remote I/O Scanner module and DeviceNet Scanner module can be additionally installed to configure I/O via Universal Remote link or DeviceNet network. The 1747-L553 processor provides shorter bit-instruction execution time of 0.37 milliseconds and 10/100 Mbps Ethernet port. Its DH+ communication port is 3 times faster than the DH-485 port. It has all the features of other SLC 5/03 processors like online programming, flash memory upgrades, floating-point math, and a built-in real-time clock, key-switch, and calendar. The 1747-L553 is intended for use in clean and dry industrial environments with a 0 to 60 degrees Celsius operating temperature and a 30G operating shock.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Allen-Bradley_1746_1747_1747-L553_Service_Manual)

Latest News

View All News