Allen-Bradley

1756-CNBR/D | Allen-Bradley ControlNet Redundant Bridge Module

  • Model 1756-CNBR/D
  • Type Power Supplies
  • Condition In Stock
4.6/5 (16 reviews)
$292.00 Indicative price · request a quote for availability

Allen-Bradley 1756-CNBR/D ControlNet redundant bridge for ControlLogix. Discontinued Dec 2024 — replacement 1756-CN2R. Fast dispatch, worldwide.

Product Description

Why the 1756-CNBR/D Still Matters on Your Line

A ControlNet link drops, and a whole process area goes dark. That is the practical cost of a single-point network failure. The Allen-Bradley 1756-CNBR/D exists to remove that risk. It is a ControlNet redundant bridge module for the ControlLogix (Bulletin 1756) platform, Series D, and it carries two redundant ControlNet channels (A/B) so communication survives a link failure instead of stopping production.

Rockwell Automation discontinued this module on 2024-12-31. The official replacement is the 1756-CN2R. That makes sourcing the 1756-CNBR/D a timing and cost decision, not just a catalog lookup.

Figure 1: Front view of the Allen-Bradley 1756-CNBR/D industrial automation component showing its physical design and enclosure.

Technical Specifications

Specification Value
Part Number 1756-CNBR/D
Manufacturer Allen-Bradley (Rockwell Automation)
Series ControlLogix / Bulletin 1756
Product Type ControlNet Redundant Bridge Module
Channels 2 (ControlNet A/B)
Backplane Current 970mA @ 5.1V, 1.7mA @ 24V
Isolation 30V
Operating Temperature 0 to 60 C (32 to 140 F)
Storage Temperature -40 to 85 C
Lifecycle Status Discontinued (2024-12-31)
Replacement 1756-CN2R

What the Numbers Mean for Uptime and Cost

Two channels are the core value here. Channel A and channel B run in parallel, so a cable break or a failed segment on one path does not stop data flow. In cost terms, that redundancy is cheap insurance against an unplanned outage.

The 970mA @ 5.1V backplane draw matters when you plan chassis loading. It is a real load on the 1756 power supply, and sizing that supply correctly avoids brownouts that take down neighbouring modules. The 1.7mA @ 24V draw is negligible, but it still counts in a full chassis budget.

30V isolation separates the ControlNet side from the backplane. In mixed industrial environments, that barrier protects the controller from transients riding in on the network cabling — a practical defence against the kind of electrical noise that shortens module life.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-CNBR/D industrial automation component.

Where This Module Fits

ControlNet redundant bridges suit fault-tolerant architectures. In oil and gas, a pipeline control segment often cannot tolerate a single network fault, so A/B redundancy keeps the controller talking to remote I/O. In water treatment, the same logic applies to pump stations spread across a site. In heavy manufacturing, redundant ControlNet protects transfer lines where a dropped link stops the whole cell.

Because the module is discontinued, the cost calculation shifts. Buyers either stock spares for existing ControlLogix installations or plan a controlled migration to the 1756-CN2R. Either path is cheaper when planned than when forced by a failure.

Installation and Integration Notes

The module mounts in a ControlLogix chassis, and any module can sit in any slot. Configuration happens in Studio 5000 Logix Designer (formerly RSLogix 5000). The chassis backplane (ControlBus) carries communication between modules, and a dedicated 1756 power supply module powers the chassis.

Wiring into a ControlNet network may require specific cabling or connection hardware. Confirm the exact cable and connector requirements with your supplier before installation. Keep the operating range of 0 to 60 C in mind when choosing a panel location, and respect the -40 to 85 C storage range for spares held in unheated stores.

Sourcing a Discontinued Module

With the 2024-12-31 discontinuation date behind us, availability tightens over time. Verify lifecycle status and stock with Oil AutoTech before ordering. If you are planning a longer-term fix, ask about the 1756-CN2R as the official replacement path.

Oil AutoTech supplies ready-to-ship spares for oil, gas and industrial automation applications, with fast dispatch, worldwide. Hands-on technical selection help is available if you need to confirm chassis compatibility or power budget before you commit.

Contact Oil AutoTech today for pricing and availability.

Specifications

Model / No. 1756-CNBR/D
Product Type Power Supplies
Brand Allen-Bradley
Condition In Stock
Origin US
Warranty 12 Month
Price $292.00

Additional Information

Allen-Bradley 1756-CNBR/D ControlNet redundant bridge module for ControlLogix, Series D. Two ControlNet A/B channels, 970mA @ 5.1V, 1.7mA @ 24V, 30V isolation, 0 to 60 C operating. Discontinued 2024-12-31; replacement 1756-CN2R. Verify availability with Oil AutoTech.

Shipping & Returns

Shipping Port
Xiamen

Downloads

Download Instruction Manual (1756-CNBR_D-1.pdf)

Latest News